C-Tec XFP502-CA XFP 2 Loop 32 Zone Addressable Fire Panel (C-TEC CAST protocol)
XFP 2 Loop 32 Zone Addressable Fire Panel (C-TEC CAST protocol)
Addressable Fire Systems C-Tec Cast XFP 1-2 Loop Fire Panels
C-TEC’s tried and trusted XFP two loop 32 zone addressable fire panel – now available with C-TEC’s own CAST digital fire alarm system protocol and fully certified to EN54 parts 2, 4 & 13.
With two powerful 40V 450mA loop drivers allowing the connection of up to 255 CAST devices per loop, the installation of a robust, feature-packed addressable fire detection and alarm system has never been easier.
Always thought of the XFP as an entry-level fire panel? Think again. Thanks to CAST’s high speed data transmission and two speedy soft addressing options (automaic via the panel or manually via a handheld programmer/device tester), it is undoubtedly one of the most powerful two loop fire panels around. This, and its ability to sit on a network of up to 8 XFP master panels, makes it ideal for use in small to medium sized stand-alone applications and larger, more sophisticated installations alike.
Technical Specifications:
| Protocol/compatibility |
C-TEC CAST. |
|---|---|
| Mains supply |
230V 50/60Hz. |
| Mains rated current |
680mA maximum. |
| Internal power supply |
27Vdc nominal. |
| Total output current limited to |
3A @ 230Vac (Imax.A 270mA; Imin. 70mA). |
| Quiescent current |
100mA (2 loops unloaded). |
| Max battery size and type |
2 x 12V 7Ah VRLA connected in series. |
| No. of loop drivers |
2. |
| Max. loop output current |
450mA (40V max). |
| Max. loop length |
1KM. |
| Max. addressable devices per loop |
255. |
| No. of conventional sounder circuits |
2 (Max. length per circuit is 500m). |
| EOL resistor value |
6800Ω 5% Tol. 0/25W (blue, grey, red, gold). |
| Max. sounder output current |
400mA. |
| Auxiliary relays |
3 x Programmable Relays (programmable from C&Es). 1 x Fault Relay (active when no faults are present). Volt free single pole changeover. Max. switch current 1A; Max. switch voltage 30Vdc. |
| Other outputs |
24V Aux. Power (19.5V min, 28V max). Protected by a resettable fuse. Max. current 100mA. |
| Auxiliary inputs |
2 x Programmable Inputs (programmable from C&Es). Connect to 0V to trigger, Max. input voltage 27V (non-latching). |
| PC connection |
PC connection via RS232 molex connector (supplied in XFP507 upload/download software kit); No printer connection available. |
| Indicators |
2 line x 40 character backlit display; 32 Zonal LEDs, General Fire; Energised; Pre-Alarm; Remote Output Activated; Remote Output Disabled; Accessed; Disablement; Test; Silenced; General Fault; Syst |
| Connections |
Fixed, largest acceptable conductor size 1mm2. |
| Expansion connections |
2-wire RS485 non-redundant network/repeater connection available via optional AFP711 network card. Max. 8 mains per network or 8 repeaters per non-networked main. Limit 1KM (main panel network) or |
| Product dimensions (mm) |
410 W x 250 H x 80 D mm (base); 439 W x 274 H x 7 D mm (lid). Hole required for semi-flush mounting = 412 W x 255 H x 50 D mm (requires XFP385 bezel). |
| Construction & finish |
Metal. |
| IP Rating |
IP30. |
| Weight |
4.5kg (without batteries). |
| Operating conditions/temperature |
-5ºC to +40ºC. Max relative humidity: 95%. |
Product Information
Product Information
Shipping & Returns
Shipping & Returns
Description
XFP 2 Loop 32 Zone Addressable Fire Panel (C-TEC CAST protocol)
Addressable Fire Systems C-Tec Cast XFP 1-2 Loop Fire Panels
C-TEC’s tried and trusted XFP two loop 32 zone addressable fire panel – now available with C-TEC’s own CAST digital fire alarm system protocol and fully certified to EN54 parts 2, 4 & 13.
With two powerful 40V 450mA loop drivers allowing the connection of up to 255 CAST devices per loop, the installation of a robust, feature-packed addressable fire detection and alarm system has never been easier.
Always thought of the XFP as an entry-level fire panel? Think again. Thanks to CAST’s high speed data transmission and two speedy soft addressing options (automaic via the panel or manually via a handheld programmer/device tester), it is undoubtedly one of the most powerful two loop fire panels around. This, and its ability to sit on a network of up to 8 XFP master panels, makes it ideal for use in small to medium sized stand-alone applications and larger, more sophisticated installations alike.
Technical Specifications:
| Protocol/compatibility |
C-TEC CAST. |
|---|---|
| Mains supply |
230V 50/60Hz. |
| Mains rated current |
680mA maximum. |
| Internal power supply |
27Vdc nominal. |
| Total output current limited to |
3A @ 230Vac (Imax.A 270mA; Imin. 70mA). |
| Quiescent current |
100mA (2 loops unloaded). |
| Max battery size and type |
2 x 12V 7Ah VRLA connected in series. |
| No. of loop drivers |
2. |
| Max. loop output current |
450mA (40V max). |
| Max. loop length |
1KM. |
| Max. addressable devices per loop |
255. |
| No. of conventional sounder circuits |
2 (Max. length per circuit is 500m). |
| EOL resistor value |
6800Ω 5% Tol. 0/25W (blue, grey, red, gold). |
| Max. sounder output current |
400mA. |
| Auxiliary relays |
3 x Programmable Relays (programmable from C&Es). 1 x Fault Relay (active when no faults are present). Volt free single pole changeover. Max. switch current 1A; Max. switch voltage 30Vdc. |
| Other outputs |
24V Aux. Power (19.5V min, 28V max). Protected by a resettable fuse. Max. current 100mA. |
| Auxiliary inputs |
2 x Programmable Inputs (programmable from C&Es). Connect to 0V to trigger, Max. input voltage 27V (non-latching). |
| PC connection |
PC connection via RS232 molex connector (supplied in XFP507 upload/download software kit); No printer connection available. |
| Indicators |
2 line x 40 character backlit display; 32 Zonal LEDs, General Fire; Energised; Pre-Alarm; Remote Output Activated; Remote Output Disabled; Accessed; Disablement; Test; Silenced; General Fault; Syst |
| Connections |
Fixed, largest acceptable conductor size 1mm2. |
| Expansion connections |
2-wire RS485 non-redundant network/repeater connection available via optional AFP711 network card. Max. 8 mains per network or 8 repeaters per non-networked main. Limit 1KM (main panel network) or |
| Product dimensions (mm) |
410 W x 250 H x 80 D mm (base); 439 W x 274 H x 7 D mm (lid). Hole required for semi-flush mounting = 412 W x 255 H x 50 D mm (requires XFP385 bezel). |
| Construction & finish |
Metal. |
| IP Rating |
IP30. |
| Weight |
4.5kg (without batteries). |
| Operating conditions/temperature |
-5ºC to +40ºC. Max relative humidity: 95%. |