🚚 Free Worldwide Shipping on All Orders!Shop Now
Product image 1
HomeStore

Hager VML112SPDRK 12 Way 100a Main Switch Consumer Unit with Type 2 Surge Protection Device(SPD) with round knockouts (Now VME113SPD)

Hager VML112SPDRK 12 Way 100a Main Switch Consumer Unit with Type 2 Surge Protection Device(SPD) with round knockouts (Now VME113SPD)

12 Way 100a Main Switch Consumer Unit with Type 2 Surge Protection Device(SPD) with round knockouts

Product Details

  • Rated & Operational Voltage (Un/Ue): 230V a.c 50 Hz
  • Rated Insulation Voltage (Ui): 320V a.c. 50Hz
  • Rated Frequency (fn): 50 Hz
  • Rated impulse withstand voltage (Uimp): 4kV
  • Rated Current of the Assembly (Ina): 100A
  • Rated Current of Assembly Circuit (Inc) Main Switch 100A (marked rated current on device)
  • Intended locations Indoor use only: Stationary assembly
  • Degree of protection:Ā  IP2XC with door open / closed and full compliment of devices / blanks fitted.
    Note: Where cables are installed through the top wall of the enclosure, gaps of IP4X to be maintained.
  • External design: Wall mounted, surface type, enclosed assembly.
  • Mechanical impact protection: IK05
  • Type of construction: Fixed parts
  • Incoming Line/Neutral terminal: 50mm2
  • Incoming Earth Terminal: 16mm2
  • Dimensions (HxWxD): 246 x 370 x 100
$34.00

Original: $97.14

-65%
Hager VML112SPDRK 12 Way 100a Main Switch Consumer Unit with Type 2 Surge Protection Device(SPD) with round knockouts (Now VME113SPD)—

$97.14

$34.00

Product Information

Shipping & Returns

Description

12 Way 100a Main Switch Consumer Unit with Type 2 Surge Protection Device(SPD) with round knockouts

Product Details

  • Rated & Operational Voltage (Un/Ue): 230V a.c 50 Hz
  • Rated Insulation Voltage (Ui): 320V a.c. 50Hz
  • Rated Frequency (fn): 50 Hz
  • Rated impulse withstand voltage (Uimp): 4kV
  • Rated Current of the Assembly (Ina): 100A
  • Rated Current of Assembly Circuit (Inc) Main Switch 100A (marked rated current on device)
  • Intended locations Indoor use only: Stationary assembly
  • Degree of protection:Ā  IP2XC with door open / closed and full compliment of devices / blanks fitted.
    Note: Where cables are installed through the top wall of the enclosure, gaps of IP4X to be maintained.
  • External design: Wall mounted, surface type, enclosed assembly.
  • Mechanical impact protection: IK05
  • Type of construction: Fixed parts
  • Incoming Line/Neutral terminal: 50mm2
  • Incoming Earth Terminal: 16mm2
  • Dimensions (HxWxD): 246 x 370 x 100